First published at 01:51 UTC on December 2nd, 2018.
managers can disable key cards & a door from opening from outside, only
fire / Panic release function = When the door is closed and the deadbolt is thrown, depress the inside to escape
VingCard door lock moc rc rfid 4.5/9v model:LCU 6333 FCC …
MORE
managers can disable key cards & a door from opening from outside, only
fire / Panic release function = When the door is closed and the deadbolt is thrown, depress the inside to escape
VingCard door lock moc rc rfid 4.5/9v model:LCU 6333 FCC id y7v-lcu6333 IC:9514a-lcu6333 4823535-d-000 1518 mana 91322 made in china
POD = power open device
RC=remote control? 7-pin connector cable from
LCU = Lock Controller Unit (RFID) (Audit trail 2000 events) to
LCA = lock case adapter & in-door electronics cassette & 4.5V ,3AA battery holder
new batteries must be connected as quickly as possible else a soft reset may take place & time must be reprogrammed into the lock
MOC = Multi-Output Controller?
Visionline wired & wireless both have
Audit trails, alarms and events over network.
Remote cancellation of keycards.
Support for room moves and extended stays without visiting front desk.
Mobile Access
Visionline Wired No need for batteries. Utilizes existing network. Fast response.
but
Visionline Wireless No need to wire door locks Online communication with locks, safes and EMS
Visionline System and Software can define criteria to create in report,
Block access to specific areas.
use counters to limit the number of times guests can access certain area,
auto activated Keycard only upon check-in , not reserve
auto de-activated upon check-out,
Visionline vs vingcard
it is possible to power open the LCU Essence RFID Assy (3G)
with a service cable and a service PC with "Lock Service 3G software"
If the door is closed and the auxiliary latch hits the striker plate/frame,
the automatic deadbolt will be thrown and the latch will be blocked
the LCU 6334 lock controller unit contains Visionline lock firmware at delivery
if it is VingCard Vision standard offline Essence , firmware must be upgraded to Visionline lock firmware
some can only be installed in non-metallic doors
Warm reset not possible on an RF ID 3G reader , Connect service cable from U..
LESS